Check Valve
Wafer Dual Plate Check Valve
  • Wafer Dual Plate Check ValveWafer Dual Plate Check Valve
  • Wafer Dual Plate Check ValveWafer Dual Plate Check Valve
  • Wafer Dual Plate Check ValveWafer Dual Plate Check Valve

Wafer Dual Plate Check Valve

The wafer dual plate check valve produced by FUXEON® adopts a double-disc spring-loaded design, featuring a lightweight structure that can accommodate various installation methods, including horizontal, vertical, and inclined pipes, offering excellent adaptability.
    Wafer · Dual Plate · Spring Assisted

    Wafer Dual Plate Check Valve for Compact Backflow Protection on Pump Lines

    The wafer dual plate check valve has two independent discs that can open and close independently based on the direction of the medium flow. The valve disc opens under the action of forward fluid pressure. When the fluid flows back or stops, due to its short stroke, it can close quickly under the force of the spring, effectively preventing media backflow and reducing water hammer impact. Because the valve structure is shorter than that of standard check valves, installation is easy and highly adaptable.

    • Ductile iron GJS500-7 body
    • CF8 / CF8M / C954 discs
    • NBR / EPDM seals
    • 2.4 MPa pressure tested
    BodyDuctile Iron GJS500-7
    DiscCF8 / CF8M / C954
    SealNBR / EPDM
    SpringSS304 / SS316
    Hinge PinSS410
    WasherPTFE
    Pressure Test2.4 MPa / 3 min
    Warranty2 Years

    Material Construction of the Wafer Dual Plate Check Valve

    The valve is built from a carefully matched set of materials so the dual plate mechanism stays durable across HVAC, water supply and industrial process duties. Disc material can be customized to match the medium and the required corrosion class, and the sealing compound is selected for the working temperature of the line.

    • BodyDuctile iron GJS500-7
    • DiscCF8 / CF8M / C954
    • SealNBR / EPDM
    • Hinge PinSS410
    • SpringSS304 / SS316
    • WasherPTFE
    • Rubber StripNBR / EPDM
    • PlugCarbon steel
    • EyeboltCarbon steel
    • SeatNBR / EPDM
    Wafer dual plate check valve body with two independent spring loaded discs
    Close view of the dual plate check valve disc and seat arrangement

    How the Double Disc Swing Check Valve Works

    1. The double disc swing check valve uses two spring-loaded valve discs (half discs). When fluid begins to flow, the valve disc opens under the resultant force (F) acting on the center of the sealing surface.

    2. The point of action of the counteracting spring bracket force (FS) is located outside the center of the valve disc face, causing the valve disc root to open first. This avoids the sealing surface friction phenomenon seen in old conventional valves when the valve disc is opened, eliminating component wear.

    3. When the flow rate slows down, the torsion spring automatically reacts, causing the disc to close and move closer to the valve body seat, reducing the closing stroke distance and time.

    4. When fluid flows backward, the valve disc gradually approaches the valve body and seat, greatly accelerating the valve's dynamic response, reducing the impact of water hammer and thus achieving impact-free performance.

    Each part of the double disc has its own spring, which provides independent closing force, allowing for greater torque applied to each disc, and the disc closes independently in response to changes in industrial fluid flow. This effect extends valve lifespan by 25% and reduces water hammer by 50%.

    Working principle diagram of the wafer dual plate check valve with flow arrows
    Spring loaded disc closing action of the dual plate check valve
    Internal view of the wafer dual plate check valve showing the independent spring assembly

    Why Choose FUXEON® Wafer Dual Plate Check Valves

    Pressure Tested on Every Batch

    Our swing check valve underwent a three-minute pressure test of 2.4 MPa, with no leakage or deformation of the valve body or bonnet. It also passed a 1.76 MPa high-pressure sealing test, with no internal leakage in the disc or seat. That quality control is repeated on each production run so the valve you receive behaves the same as the one that was tested.

    Pressure test of the wafer dual plate check valve at 2.4 MPa
    High pressure sealing test on the dual plate check valve seat

    Epoxy Coating for Corrosion Resistance

    The sealing and corrosion resistance of double-disc check valves are extremely important, as they determine the valve's function and lifespan. Therefore, we apply a red epoxy resin anti-corrosion coating to the valve body, which can enhance the valve's corrosion resistance and keep the durable body performing in water supply, HVAC and light chemical service. The difference against an uncoated body is visible on the image below.

    Dual plate check valve with red epoxy anti-corrosion coating from FUXEON
    FUXEON valves with anti-corrosion coating
    Valve without anti-corrosion coating for comparison
    Valves without anti-corrosion coating

    As a China manufacturer with in-house machining and assembly, we can offer customized disc material, spring grade and coating for your project, keep an advanced production line for consistent quality, and provide a discount on volume orders. Ask for the pressure test record and coating specification together with your quotation, or review our production equipment and certificates.

    Application Areas of the Double Door Check Valve

    Double door check valves are suitable for installation in confined spaces, HVAC circulating water, small to medium-sized pump outlet renovations, and clamp double-valve check valves for purified pipelines and industrial, environmental protection, water treatment and high-rise building water supply and drainage pipelines to prevent reverse flow of media. For example, in drainage systems, pump outlets prevent backflow and the double-lobe structure resists water hammer.

    • HVAC circulating water
    • Pump outlet retrofit
    • Confined installation space
    • Water treatment
    • High-rise water supply
    • Industrial drainage
    • Environmental protection

    For fire protection systems, pair this valve with a fire pump at the discharge line, or combine it with a gate valve and other check valves to build a complete pump station. Browse the full fire fighting equipment range for matching components.

    Wafer dual plate check valve installed on an industrial pump discharge line

    Installation and Maintenance

    Installation

    1. When installing the double valve check valve, the medium flow direction must be consistent with the valve body arrow.
    2. The flanges at both ends must be clamped evenly. Do not press tightly on one side, to prevent the rubber lining from squeezing and falling off.
    3. When used in large-diameter pipelines, short pipe supports are needed to reduce valve axial pressure.

    Maintenance

    1. Shut down every month to flush the gypsum crystals inside the valve to prevent jamming and improper closing.
    2. Check every six months for bulging or peeling of the rubber lining layer, and whether the valve plate has erosion or wear.
    3. If the spring becomes fatigued or the valve is not properly closed, directly replace the 316L anti-corrosion spring; there is no need to replace the entire valve.
    Installation of the wafer dual plate check valve between flanges
    Routine maintenance inspection of the dual plate check valve

    Frequently Asked Questions

    Can I install the Dual Plate Check Valve at the pump outlet?

    Of course, this prevents pump-stop slurry from flowing back into the absorption tower and avoids pump body reversal damaging the impeller and seals.

    Which working conditions are not suitable for choosing it?

    Contains a large amount of particles, is prone to scaling, and has high viscosity, which can easily jam the valve disc or spring. Frequent pulsation, high temperature and severe corrosion conditions require special attention to verifying the spring's temperature resistance and sealing materials.

    Why does the Dual Plate Check Valve still flow back after the pump is stopped?

    Common causes include wear on the sealing surface, impurities stuck at the sealing point, valve disc not closing properly, and spring failure. On-site, you can first check the flow direction and clean out impurities, then test the seal and spring condition.

    How long is the delivery time?

    It depends on the exact quantity. Customized models have longer delivery times than regular models.

    How long is the warranty period?

    In cases of non-human damage and product quality issues, return and exchange service is provided within two years.

    Which disc material should I choose for my medium?

    CF8 covers most water and HVAC duties, CF8M (SS316) is preferred for chloride-bearing or mildly corrosive media, and C954 aluminium bronze is often selected for seawater-adjacent or high-load applications. Tell us the medium and we will confirm the disc and seal pairing.

    Do you offer a discount for bulk or project orders?

    Yes. A discount is available for distributor and project quantities. Share your annual demand or bill of quantities and our sales team will prepare a tiered quotation with the delivery schedule.

    Get a Quotation for Your Wafer Dual Plate Check Valve

    Send us the line size, medium, pressure rating and required disc material, and our team will reply with a customized configuration, drawing confirmation and delivery schedule.

    Send Inquiry
    Contact Info
    If you have any enquiry about quotation or cooperation, please feel free to email or use the following inquiry form. Our sales representative will contact you within 24 hours.
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept