A water curtain sprinkler spends its life full of water and often in humid, fume-laden air. If the body corrodes, the slot geometry changes, the spray pattern distorts and the water wall develops gaps. The corrosion resistant water curtain sprinkler from FUXEON® is precision cast in brass — a material chosen specifically for its resistance to corrosion, its dimensional stability and its long service life under higher water pressure with minimal deformation.
The result is a nozzle with a smooth, burr-free surface that provides stable performance and even water distribution during operation. Every unit is intended for the long term: the slot stays clean, the fan stays uniform, and the curtain stays continuous.
Brass — a copper-zinc alloy — forms a thin, stable oxide layer on its surface that slows further attack. In fire protection service this matters for three reasons:
|
Property |
Benefit in Service |
|
Corrosion resistance |
Withstands humid air, condensate and many mildly aggressive fumes without pitting |
|
Dimensional stability |
Slot geometry is retained over time, so the water curtain pattern does not drift |
|
Pressure resistance |
Handles higher water pressure with minimal deformation compared with plastics |
|
Machinability |
Precision casting gives high accuracy and a smooth, burr-free surface |
Plastic nozzles are sometimes offered at lower cost, but they are prone to breakage during installation and to deformation under pressure. A deformed slot produces an uneven curtain — precisely the failure mode a water curtain cannot afford.
|
Model |
K Flow |
Water Curtain Tilt Angle |
Water Curtain Spray Angle |
Structural Form |
Connection Thread |
Min. Working Pressure (MPa) |
|
ZSTM A-T28/175 |
28 |
0° |
175° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM A-T40/175 |
40 |
0° |
175° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM B-T28/160 |
28 |
90° |
160° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM B-T40/160 |
40 |
90° |
160° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM B-T60/160 |
60 |
90° |
160° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM C-T40/160 |
40 |
90° |
160° |
Double Slot Type |
R1/2 |
0.10 |
|
ZSTM C-T60/160 |
60 |
90° |
160° |
Double Slot Type |
R1/2 |
0.10 |
|
NO. |
Spray Point Height (m) |
Water Spray Intensity L/(s·m) |
Working Pressure (MPa) |
|
Fireproof water curtain |
≤12 |
2.0 |
0.1 |
|
Protective cooling water curtain |
≤4 |
0.5 |
0.1 |
If the spray point height of the protective cooling water curtain exceeds 4 meters, then for every 1 m increase, the spray intensity should increase by 0.1 L/(s·m). Because the brass body holds its slot geometry, the designed spray intensity can be relied on over the life of the installation rather than degrading as the nozzle ages.
Water curtain sprinklers are divided into two types according to fire protection method. Both are available in the same corrosion-resistant brass construction:
Drencher sprinklers typically form a water curtain fire suppression system together with control valves, detection systems, alarm systems and piping. On a fire signal from detectors or a manual alarm, the control valve — such as a deluge alarm valve — opens, the fire pump starts, and high-pressure water reaches the sprinklers through the piping network. As water flows through the nozzles, dense granular droplets are sprayed in a predetermined direction, quickly forming a continuous water curtain or water wall.
Our water curtain sprinkler has obtained China Fire Protection Product Certification. Certificate information can be checked at www.cccf.com.cn, and the full document set is available on our certificate page.
A: The body and deflector are precision cast in brass. Brass forms a stable surface oxide that resists humid air, condensate and many mildly aggressive fumes, and it holds its slot geometry over a long service life.
A: Corrosion roughens the slot and can narrow or distort it. The fan then becomes uneven and the curtain develops gaps — exactly where fire and smoke will pass. A corrosion-resistant body protects the pattern, not just the appearance.
A: Yes for fire protection service. Plastic is prone to breakage during installation and to deformation under pressure, and a deformed slot produces an uneven curtain. Brass provides high machining accuracy, pressure resistance and dimensional stability.
A: No. The K values, tilt angles and spray angles are the same as the standard range, and all models operate at a minimum working pressure of 0.10 MPa.
A: Flush the line periodically, keep the slot free of scale and debris, and avoid scratching the brass surface during installation. Do not use aggressive acid cleaners on the nozzle.
A: Yes. We support brand customization and can produce other text content as required. Contact us through the inquiry page to discuss OEM/ODM options.
Looking for a water curtain sprinkler that holds its pattern over the long term?
OEM / ODM available · CCCF certified · Export to 50+ countries