Products

Corrosion Resistant Water Curtain Sprinkler

A water curtain sprinkler spends its life full of water and often in humid, fume-laden air. If the body corrodes, the slot geometry changes, the spray pattern distorts and the water wall develops gaps. The corrosion resistant water curtain sprinkler from FUXEON® is precision cast in brass — a material chosen specifically for its resistance to corrosion, its dimensional stability and its long service life under higher water pressure with minimal deformation.

The result is a nozzle with a smooth, burr-free surface that provides stable performance and even water distribution during operation. Every unit is intended for the long term: the slot stays clean, the fan stays uniform, and the curtain stays continuous.

Why Brass Is the Corrosion-Resistant Choice

Brass — a copper-zinc alloy — forms a thin, stable oxide layer on its surface that slows further attack. In fire protection service this matters for three reasons:

Property

Benefit in Service

Corrosion resistance

Withstands humid air, condensate and many mildly aggressive fumes without pitting

Dimensional stability

Slot geometry is retained over time, so the water curtain pattern does not drift

Pressure resistance

Handles higher water pressure with minimal deformation compared with plastics

Machinability

Precision casting gives high accuracy and a smooth, burr-free surface

Plastic nozzles are sometimes offered at lower cost, but they are prone to breakage during installation and to deformation under pressure. A deformed slot produces an uneven curtain — precisely the failure mode a water curtain cannot afford.

Technical Parameters

Model

K Flow

Water Curtain Tilt Angle

Water Curtain Spray Angle

Structural Form

Connection Thread

Min. Working Pressure (MPa)

ZSTM A-T28/175

28

0°

175°

Single Slot Type

R1/2

0.10

ZSTM A-T40/175

40

0°

175°

Single Slot Type

R1/2

0.10

ZSTM B-T28/160

28

90°

160°

Single Slot Type

R1/2

0.10

ZSTM B-T40/160

40

90°

160°

Single Slot Type

R1/2

0.10

ZSTM B-T60/160

60

90°

160°

Single Slot Type

R1/2

0.10

ZSTM C-T40/160

40

90°

160°

Double Slot Type

R1/2

0.10

ZSTM C-T60/160

60

90°

160°

Double Slot Type

R1/2

0.10

Spray Intensity and System Design

NO.

Spray Point Height (m)

Water Spray Intensity L/(s·m)

Working Pressure (MPa)

Fireproof water curtain

≤12

2.0

0.1

Protective cooling water curtain

≤4

0.5

0.1

If the spray point height of the protective cooling water curtain exceeds 4 meters, then for every 1 m increase, the spray intensity should increase by 0.1 L/(s·m). Because the brass body holds its slot geometry, the designed spray intensity can be relied on over the life of the installation rather than degrading as the nozzle ages.

Two Fire Protection Methods, One Corrosion-Resistant Body

Water curtain sprinklers are divided into two types according to fire protection method. Both are available in the same corrosion-resistant brass construction:

  • Fireproof water curtain: a dense water wall directly blocks fire and smoke. Used at large openings and passageways where a physical firewall cannot be installed.
  • Protective cooling water curtain: water is sprayed directly onto the protected object — fire-resistant roller shutters, fire-resistant glass walls, doors and windows — and the water film cools the surface and enhances its fire resistance.

System Composition and Working Principle

Drencher sprinklers typically form a water curtain fire suppression system together with control valves, detection systems, alarm systems and piping. On a fire signal from detectors or a manual alarm, the control valve — such as a deluge alarm valve — opens, the fire pump starts, and high-pressure water reaches the sprinklers through the piping network. As water flows through the nozzles, dense granular droplets are sprayed in a predetermined direction, quickly forming a continuous water curtain or water wall.

Installation Locations

  1. Stage openings in first-class and second-class theaters, other theaters with more than 1,500 seats, auditoriums or halls with more than 2,000 seats, and theaters or auditoriums with more than 800 seats in high-rise civil buildings, as well as openings connecting the stage to side stages and backstage areas.
  2. Local openings where fire-resistant partitions such as firewalls cannot be installed.
  3. The upper part of fire-resistant roller shutters or fire curtains that require protection and cooling.

Certification

Our water curtain sprinkler has obtained China Fire Protection Product Certification. Certificate information can be checked at www.cccf.com.cn, and the full document set is available on our certificate page.

Frequently Asked Questions

Q: What makes this sprinkler corrosion resistant?

A: The body and deflector are precision cast in brass. Brass forms a stable surface oxide that resists humid air, condensate and many mildly aggressive fumes, and it holds its slot geometry over a long service life.

Q: How does corrosion affect a water curtain?

A: Corrosion roughens the slot and can narrow or distort it. The fan then becomes uneven and the curtain develops gaps — exactly where fire and smoke will pass. A corrosion-resistant body protects the pattern, not just the appearance.

Q: Is brass better than plastic for water curtain sprinklers?

A: Yes for fire protection service. Plastic is prone to breakage during installation and to deformation under pressure, and a deformed slot produces an uneven curtain. Brass provides high machining accuracy, pressure resistance and dimensional stability.

Q: Does the corrosion-resistant body change the hydraulic performance?

A: No. The K values, tilt angles and spray angles are the same as the standard range, and all models operate at a minimum working pressure of 0.10 MPa.

Q: How should the sprinkler be maintained to preserve corrosion resistance?

A: Flush the line periodically, keep the slot free of scale and debris, and avoid scratching the brass surface during installation. Do not use aggressive acid cleaners on the nozzle.

Q: Can I get brand customization on the corrosion-resistant sprinkler?

A: Yes. We support brand customization and can produce other text content as required. Contact us through the inquiry page to discuss OEM/ODM options.

Looking for a water curtain sprinkler that holds its pattern over the long term?

OEM / ODM available · CCCF certified · Export to 50+ countries

Send InquiryContact Us

Hot Products

  • Single Jacket Fire Hose

    Single Jacket Fire Hose

    The single jacket fire hose supplied by FUXEON® features high-pressure resistance, low-temperature resistance, corrosion resistance, and wear resistance, providing excellent service experience for various industries such as firefighting, petroleum, chemical, and agriculture. If you have specific requirements for the fire hose, welcome to contact us for customization.
  • Pistol Grip Fire Nozzle

    Pistol Grip Fire Nozzle

    The FUXEON® Pistol Grip Fire Nozzle is a professional fire-fighting terminal device developed and manufactured by a senior Chinese fire-fighting equipment manufacturer. Leveraging its lightweight materials, constant flow design, and double-layer fire-resistant water curtain, it combines convenience and safety, and is compatible with various connection methods. As a reliable fire-fighting equipment supplier, FUXEON® maintains quality control through standardized factories, providing efficient solutions for global fire-fighting and emergency scenarios. Inquiries are welcome.
  • OSY Gate Valve

    OSY Gate Valve

    FUXEON®'s OSY Gate Valve is FM approved and available in sizes ranging from DN50 to DN300 (2”-12”). The valve body is primarily made of ductile iron, but stainless steel is also available. It is one of the most important components in fire protection systems. Customization is also available to meet your specific needs.
  • Deluge Alarm Valve

    Deluge Alarm Valve

    The Fuxeon® Deluge Alarm Valve is a common fire protection component that plays a vital role in deluge and water curtain systems. It's also our best-selling product. As a supplier of this product, please contact us for custom designs.
  • JIS Machino Coupling

    JIS Machino Coupling

    The FUXEON® JIS Machino Coupling is a quick-connect component designed for connecting fire hoses, fire trucks, landing valves, fire hydrants, and nozzles. It uses an internal slider and slot-locking structure to provide a fast connection without the multiple rotations required by conventional threaded interfaces.
  • Signal Gate Valve

    Signal Gate Valve

    FUXEON® Signal Gate Valve is a highly reliable resilient-seated valve available in various models. Thanks to its scientific design, premium materials, and triple-safety sealing system, it boasts excellent sealing, corrosion resistance, and durability. As a professional manufacturer, we provide high-performance products to global customers, widely used in fire protection, water supply and drainage, and petrochemical pipelines. As a trusted Chinese supplier, we have earned global recognition.

Send Inquiry

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept