In an emergency, the value of a fire monitor is measured in seconds, not specifications. The FUXEON® fire monitor for emergency firefighting is built for exactly that reality: a portable, self-supporting water cannon that goes from folded storage to full-flow operation in the shortest possible time. It delivers a rated flow of 40 L/S (634 GPM) at 0.8 MPa, giving first responders a powerful stream where fixed monitors cannot reach.
The unit is designed around three emergency requirements — fast setup, stable footing on uncertain ground, and operation by a small crew. Every design detail, from the spring-loaded leg latches to the self-adjusting shock absorbers, serves one of those three goals.
Quick Specifications: Model PSY8/40WB-FX | Rated Flow 40 L/S (634 GPM) | Rated Pressure 0.8 MPa | Max Shooting Range ≥65 m | Inlet 2.5" GOST / STORZ / NH (Optional)
The fire monitor for emergency firefighting has multiple support legs that fold for compact storage and extend for operation. Spring-loaded latches secure the legs in both positions, so there are no pins to lose and no tools to find. Each leg carries anti-slip tungsten carbide studs that grip the ground, and internal spring-loaded shock-absorbing mechanisms that automatically adjust to uneven surfaces and cushion recoil.
Once deployed, the monitor acts as an independent automated unit: it can swing automatically without human intervention while the crew attends to hose connections or foam supply. With a 360° rotating base, the coverage arc is wide enough to protect a tank area or a loading bay from a single position.
|
Item \ Model |
PSY8/40WB-FX |
|
Rated Working Pressure (MPa) |
0.8 |
|
Working Pressure Range (MPa) |
0.8~1.0 |
|
Rated Flow Rate (L/S) |
40 |
|
Max. Shooting Range (≥M) |
65 |
|
Max. Fog / Spray Angle (°) |
≥90 |
|
Elevation Angle (°) |
+30~+70 |
|
Horizontal Rotation Angle (°) |
≥20 |
|
Inlet Connection |
2.5" GOST, STORZ, Instantaneous, NH, etc. (Optional) |
|
Scenario |
Primary Risk |
Suggested Setup |
|
Tank farm rim fire |
Rapid spread, heat radiation |
Elevation 45°–60°, straight jet, monitor positioned upwind behind a bund |
|
Loading arm leak fire |
Flash fire, toxic vapor |
Spray mode for vapor dispersion, elevated angle to reach the arm |
|
Dock or jetty incident |
Wind-driven spread, limited access |
Legs angled outward on the concrete deck, safety belt to a bollard |
|
Old urban area, narrow lane |
Fire truck cannot enter |
Carry the folded unit on foot, deploy at the lane entrance, long-range jet |
Extend the support legs of the fire monitor for emergency firefighting and place it on a flat, relatively rough surface, ensuring the three spikes are as deeply embedded as possible into the ground. Secure the auxiliary safety belt to fixed equipment around the monitor. Close the valve, adjust the elevation angle to >30°, connect the water supply hose, and slowly open the valve to reach the rated flow and pressure. Begin firefighting immediately after confirming the jet is stable.
If the supply pressure is marginal, keep the elevation angle high and the pattern narrow — this preserves distance even when flow is below the rated value. If the monitor must be repositioned during the operation, close the valve first; never drag a pressurized monitor by its legs.
Emergency readiness depends on storage discipline. Keep the monitor folded, latched and clean, in a dry cabinet or on a response trolley near the hazard area. Grease the rotation joint every few months, check that the leg latches spring back freely, and inspect the tungsten carbide studs for wear. A monitor that is stored correctly is a monitor that deploys correctly. For related equipment, see our fire cabinet and fire hose reel ranges.
A: The folding legs with spring-loaded latches let a trained crew extend and lock the base in seconds. Total time to water depends mainly on how quickly the hose can be connected and the supply valve opened.
A: Yes. The aluminum alloy body is substantially lighter than equivalent steel monitors, and the legs extend without tools. For safety, a second person should handle the hose connection while the first stabilizes the monitor.
A: The spring-loaded shock absorbers inside each leg automatically adjust to uneven surfaces. On soft ground, press the studs in firmly; on hard ground, angle the legs outward to widen the base.
A: At full rated flow the reaction force is significant. The three-point base, tungsten carbide studs and shock absorbers are designed to hold position, but the auxiliary safety belt should always be attached as a backup.
A: The inlet is available in GOST, STORZ, Instantaneous and NH configurations. Keeping a matching adapter on the response trolley is the simplest way to avoid a mismatch during an emergency.
A: Folded, latched, drained and dry, ideally in a cabinet or on a trolley near the hazard zone. Grease the joints periodically and check the leg latches and studs for wear.
Equip your emergency response team with the FUXEON® fire monitor for emergency firefighting.
OEM / ODM available · No MOQ · Ships to 50+ countries