Products

Metal Water Curtain Sprinkler Nozzle

The metal water curtain sprinkler nozzle is the discharge head at the heart of a drencher system. Its job is to convert pressurized water into a dense, continuous sheet of droplets that behaves like a physical barrier. FUXEON® manufactures this nozzle by precision casting in brass, which gives high machining accuracy, a smooth burr-free surface, stable performance and even water distribution during operation.

The nozzle is available in single-slot and double-slot types, with K values of 28, 40 and 60, tilt angles of 0° and 90°, and spray angles of 175° and 160°. All models share an R1/2 connection thread and a minimum working pressure of 0.10 MPa, so a single system design can use different heads for different parts of the same water curtain line.

How the Metal Nozzle Forms a Water Curtain

Water enters the R1/2 inlet and is forced through a machined slot — a semi-circular opening in the single-slot type, or a pair of openings in the double-slot type. Under pressure, the water exits as a fan-shaped sheet that breaks into dense granular droplets. The tilt angle determines whether the sheet discharges straight down (0°) or is directed sideways (90°), while the spray angle defines the width of the fan.

Design Element

Effect on the Water Curtain

Slot type

Single slot produces one fan; double slot produces two fans for wider coverage or two-sided protection

K value (28 / 40 / 60)

Sets the flow through the nozzle at a given pressure; higher K means more water and a denser curtain

Tilt angle (0° / 90°)

Directs the curtain downward or sideways relative to the pipe axis

Spray angle (175° / 160°)

Defines the fan width and therefore the overlap between adjacent nozzles

Technical Parameters

Model

K Flow

Water Curtain Tilt Angle

Water Curtain Spray Angle

Structural Form

Connection Thread

Min. Working Pressure (MPa)

ZSTM A-T28/175

28

0°

175°

Single Slot Type

R1/2

0.10

ZSTM A-T40/175

40

0°

175°

Single Slot Type

R1/2

0.10

ZSTM B-T28/160

28

90°

160°

Single Slot Type

R1/2

0.10

ZSTM B-T40/160

40

90°

160°

Single Slot Type

R1/2

0.10

ZSTM B-T60/160

60

90°

160°

Single Slot Type

R1/2

0.10

ZSTM C-T40/160

40

90°

160°

Double Slot Type

R1/2

0.10

ZSTM C-T60/160

60

90°

160°

Double Slot Type

R1/2

0.10

Slot Types and Their Applications

Single-slot nozzles discharge a single fan-shaped curtain. They are the default choice for a straight water wall along an opening, where the fan from one nozzle overlaps the fan from its neighbour to produce an unbroken sheet.

Double-slot nozzles discharge two fans from one body. They are useful where the curtain must protect two adjacent zones at once — for example at a corner, on a shared mullion between two openings, or where the pipe run is short and more coverage is needed per nozzle position.

The tilt angle is equally practical. A 0° head throws the curtain straight down from a horizontal pipe, which suits protection above a roller shutter. A 90° head throws the curtain sideways, which suits a vertical water wall across a passageway or a proscenium opening.

Spray Intensity Design Values

NO.

Spray Point Height (m)

Water Spray Intensity L/(s·m)

Working Pressure (MPa)

Fireproof water curtain

≤12

2.0

0.1

Protective cooling water curtain

≤4

0.5

0.1

If the spray point height of the protective cooling water curtain exceeds 4 meters, then for every 1 m increase, the spray intensity should increase by 0.1 L/(s·m).

Arranging the Nozzles

Nozzle layout follows three steps: calculate the required flow from the opening width; divide by the flow of a single nozzle at the K value and 0.10 MPa working pressure to get the theoretical number of nozzles; then arrange the heads in single, double or triple rows and perform hydraulic calculations to fix pipe diameter, flow and pressure. The fire pump and deluge alarm valve are sized from the same calculation.

Frequently Asked Questions

Q: How do I read the model code on a metal water curtain nozzle?

A: The letter after ZSTM indicates the tilt angle: Code A is 0°, Code B is 90° with one outlet, Code C is 90° with two outlets, and Code D is any other angle. The letters G, L and T indicate the intended function: G for fire separation only, L for protective cooling only, and T for general purpose covering both.

Q: What does the K value actually change?

A: The K value sets the flow through the nozzle at a given pressure. At 0.10 MPa, a K28 nozzle passes less water than a K60 nozzle, so higher K values produce a denser curtain but require more supply capacity.

Q: When should I use 175° instead of 160° spray angle?

A: The 175° fan is wider and is used with the 0° tilt heads to cover a broad downward curtain. The 160° fan is used with the 90° tilt heads for sideways curtains where a slightly narrower, more concentrated sheet is wanted.

Q: Can the nozzle be installed on a vertical pipe?

A: Yes, but the tilt angle must be chosen to suit the pipe orientation. A 90° head on a vertical pipe throws the curtain horizontally; a 0° head on a vertical pipe would throw it sideways along the pipe axis, which is rarely what the design intends.

Q: What water pressure should the system deliver to the nozzle?

A: The minimum working pressure is 0.10 MPa, and the design spray intensities in the table assume 0.1 MPa at the nozzle. Confirm the pressure at the most remote head, not only at the pump.

Q: How many nozzles do I need for a given opening?

A: Calculate the total flow from the opening width and required spray intensity, divide by the single-nozzle flow at 0.10 MPa for the chosen K value, then arrange in one or more rows with adequate overlap. Our engineers can run the layout for you via the inquiry page.

Need help selecting the right metal water curtain sprinkler nozzle for your layout?

OEM / ODM available · CCCF certified · Export to 50+ countries

Send InquiryContact Us

Hot Products

  • Manual Butterfly Valve

    Manual Butterfly Valve

    The FUXOEN® manual butterfly valve is a valve that controls fluid flow or cuts off fluid flow by rotating a circular valve disc. It has a simple structure, small size, light weight, and quick opening and closing, and is one of the most commonly used control valves in industrial, water supply and drainage, fire protection, heating, ventilation, and chemical pipeline systems. Our factory provides OEM services, welcome to consult us.
  • BSP Fire Nozzle

    BSP Fire Nozzle

    The high-quality BSP Fire Nozzle of FUXEON® can adjust the water flow according to different locations and fire conditions. It is mainly suitable for extinguishing and cooling various fires, significantly improving the safety of firefighters and serving as an important tool for firefighting.
  • JIS Machino Coupling

    JIS Machino Coupling

    The FUXEON® JIS Machino Coupling is a quick-connect component designed for connecting fire hoses, fire trucks, landing valves, fire hydrants, and nozzles. It uses an internal slider and slot-locking structure to provide a fast connection without the multiple rotations required by conventional threaded interfaces.
  • KPA Fire Hydrant

    KPA Fire Hydrant

    The FUXEON® KPA fire hydrant is a device that connects to underground fire hydrants. Its function is to open or close the hydrant and connect fire hoses to provide water to fire and rescue departments. This fire hydrant is suitable for temperate, cold, and tropical climates and meets the installation requirements specified in GOST 15150-69 standard.
  • Simplex Basket Strainer

    Simplex Basket Strainer

    The simplex basket strainer produced by FUXEON® is a small device designed to remove small amounts of solid particles from liquids or gases. It is usually installed on pipelines to protect the normal operation of critical equipment such as compressors, pumps, and instruments by intercepting impurities.
  • ABC Dry Powder Fire Extinguisher

    ABC Dry Powder Fire Extinguisher

    FUXEON® ABC dry powder fire extinguishers are filled with ABC dry powder (main component: ammonium phosphate), which has good flowability, strong anti-caking properties, is non-toxic, odorless, and non-conductive, and can be stored for a long time. They are widely used in homes, chemical plants, libraries, docks, fuel depots, boiler rooms, warehouses, and other places, and are an indispensable fire safety equipment.You can obtain free samples through our website.

Send Inquiry

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept