The metal water curtain sprinkler nozzle is the discharge head at the heart of a drencher system. Its job is to convert pressurized water into a dense, continuous sheet of droplets that behaves like a physical barrier. FUXEON® manufactures this nozzle by precision casting in brass, which gives high machining accuracy, a smooth burr-free surface, stable performance and even water distribution during operation.
The nozzle is available in single-slot and double-slot types, with K values of 28, 40 and 60, tilt angles of 0° and 90°, and spray angles of 175° and 160°. All models share an R1/2 connection thread and a minimum working pressure of 0.10 MPa, so a single system design can use different heads for different parts of the same water curtain line.
Water enters the R1/2 inlet and is forced through a machined slot — a semi-circular opening in the single-slot type, or a pair of openings in the double-slot type. Under pressure, the water exits as a fan-shaped sheet that breaks into dense granular droplets. The tilt angle determines whether the sheet discharges straight down (0°) or is directed sideways (90°), while the spray angle defines the width of the fan.
|
Design Element |
Effect on the Water Curtain |
|
Slot type |
Single slot produces one fan; double slot produces two fans for wider coverage or two-sided protection |
|
K value (28 / 40 / 60) |
Sets the flow through the nozzle at a given pressure; higher K means more water and a denser curtain |
|
Tilt angle (0° / 90°) |
Directs the curtain downward or sideways relative to the pipe axis |
|
Spray angle (175° / 160°) |
Defines the fan width and therefore the overlap between adjacent nozzles |
|
Model |
K Flow |
Water Curtain Tilt Angle |
Water Curtain Spray Angle |
Structural Form |
Connection Thread |
Min. Working Pressure (MPa) |
|
ZSTM A-T28/175 |
28 |
0° |
175° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM A-T40/175 |
40 |
0° |
175° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM B-T28/160 |
28 |
90° |
160° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM B-T40/160 |
40 |
90° |
160° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM B-T60/160 |
60 |
90° |
160° |
Single Slot Type |
R1/2 |
0.10 |
|
ZSTM C-T40/160 |
40 |
90° |
160° |
Double Slot Type |
R1/2 |
0.10 |
|
ZSTM C-T60/160 |
60 |
90° |
160° |
Double Slot Type |
R1/2 |
0.10 |
Single-slot nozzles discharge a single fan-shaped curtain. They are the default choice for a straight water wall along an opening, where the fan from one nozzle overlaps the fan from its neighbour to produce an unbroken sheet.
Double-slot nozzles discharge two fans from one body. They are useful where the curtain must protect two adjacent zones at once — for example at a corner, on a shared mullion between two openings, or where the pipe run is short and more coverage is needed per nozzle position.
The tilt angle is equally practical. A 0° head throws the curtain straight down from a horizontal pipe, which suits protection above a roller shutter. A 90° head throws the curtain sideways, which suits a vertical water wall across a passageway or a proscenium opening.
|
NO. |
Spray Point Height (m) |
Water Spray Intensity L/(s·m) |
Working Pressure (MPa) |
|
Fireproof water curtain |
≤12 |
2.0 |
0.1 |
|
Protective cooling water curtain |
≤4 |
0.5 |
0.1 |
If the spray point height of the protective cooling water curtain exceeds 4 meters, then for every 1 m increase, the spray intensity should increase by 0.1 L/(s·m).
Nozzle layout follows three steps: calculate the required flow from the opening width; divide by the flow of a single nozzle at the K value and 0.10 MPa working pressure to get the theoretical number of nozzles; then arrange the heads in single, double or triple rows and perform hydraulic calculations to fix pipe diameter, flow and pressure. The fire pump and deluge alarm valve are sized from the same calculation.
A: The letter after ZSTM indicates the tilt angle: Code A is 0°, Code B is 90° with one outlet, Code C is 90° with two outlets, and Code D is any other angle. The letters G, L and T indicate the intended function: G for fire separation only, L for protective cooling only, and T for general purpose covering both.
A: The K value sets the flow through the nozzle at a given pressure. At 0.10 MPa, a K28 nozzle passes less water than a K60 nozzle, so higher K values produce a denser curtain but require more supply capacity.
A: The 175° fan is wider and is used with the 0° tilt heads to cover a broad downward curtain. The 160° fan is used with the 90° tilt heads for sideways curtains where a slightly narrower, more concentrated sheet is wanted.
A: Yes, but the tilt angle must be chosen to suit the pipe orientation. A 90° head on a vertical pipe throws the curtain horizontally; a 0° head on a vertical pipe would throw it sideways along the pipe axis, which is rarely what the design intends.
A: The minimum working pressure is 0.10 MPa, and the design spray intensities in the table assume 0.1 MPa at the nozzle. Confirm the pressure at the most remote head, not only at the pump.
A: Calculate the total flow from the opening width and required spray intensity, divide by the single-nozzle flow at 0.10 MPa for the chosen K value, then arrange in one or more rows with adequate overlap. Our engineers can run the layout for you via the inquiry page.
Need help selecting the right metal water curtain sprinkler nozzle for your layout?